Advanced TOFD Solutions for Critical Weld Assessment

Time of Flight Diffraction (TOFD) uses diffracted ultrasonic signals from defect tips for precise weld flaw detection, sizing in pipelines, vessels, tanks. Tove Leeds positions transmitter-receiver pairs across welds, measuring time-of-flight for depth/height accuracy to 0.1mm.

Replaces radiography in oil & gas girth welds, power boiler headers; excels thick sections (12-200mm), vertical cracks. Insensitive to orientation unlike pulse-echo.

Combines with PAUT; ASNT-certified techs calibrate per BS 7706/ISO, produce B-scans, reports for fitness-for-service, growth monitoring.

Why Choose Tove Leeds?

Accurate Defect Sizing

TOFD measures diffracted signals from crack tips, providing precise height sizing within tenths of a millimeter.

Rapid Weld Coverage

Single-pass scanning inspects entire weld volume in one scan.

Digital Data Recording

All inspection data is digitally recorded and stored for future comparison.

Radiation-Free Safety

TOFD eliminates ionizing radiation hazards, enabling inspection during production without evacuation.